產(chǎn)品介紹

EA-PS 10750-40 3U為德國EA最新推出的高精度直流電源,在進(jìn)口直流電源中被廣泛用于汽車測試電源等領(lǐng)域。
EA-PS 10750-40 3U產(chǎn)品技術(shù)規(guī)格書(點(diǎn)擊右鍵另存為)德國EA代理,上海雨芯儀器科技有限公司提供
EA-PS 10750-40 3U Features 
Wide range input, 208 V - 480 V +10 % 3ph AC 
Active Power-Factor-Correction, typical 0.99 
Very high efficiency up to over 96 % 
High performance of 15 kW per unit 
Voltage from 0 - 60 V up to 0 - 2000 V 
Currents from 0 - 20 A up to 0 - 510 A 
Flexible power regulated DC output stages  
(autoranging) 
Regulation mode CV, CC, CP with fast crossover 
Digital regulation, high resolution with 16bit ADCs and  
DACs, selection of control speed: Normal, Fast, Slow 
Color 5“ TFT display with touch control and intuitive user interface 
Galvanically isolated Share-Bus for parallel operation of all power classes in the 10000 series 
Master-Slave bus for parallel operation of up to 64 units of all power classes in the 10000 series 
Command languages and drivers: SCPI and ModBus,LabVIEW, IVI
Build-in Interfaces 
USB  
Ethernet 
Analog 
USB Host 
Master-Slave-Bus 
Share-Bus 
Software 
EA-Power Control 
Optional Interfaces 
CAN 
CANopen 
RS232 
Profibus 
EtherCAT 
Profinet, with one or two ports 
Modbus, with one or two ports 
 Ethernet, with one or two ports
| Technical Specifications | EA-PS 10750-40 3U | 
| DC-Output | |
| Voltage range | 0 - 750V | 
| Ripple rms CV | ≤200 mV BW 300 kHz | 
| Ripple and noise p-p CV | ≤800 mV BW 20 MHz | 
| Current range | 0 - 40 A | 
| Power range *1 | 0 - 10000 W | 
| Output capacity | 360 μF | 
| Efficiency up to | 95.5% *1 | 
| Isolation | |
| Negative DC-Pol <-> PE | ±1500 V DC | 
| Positive DC-Pol <-> PE | +2000 V DC | 
| Article number | 06230954 | 
*1 100% Power and 100% Output voltage
| EA-PS 10750-40 3U General specifications | |
| AC-Input | |
| Voltage, Phases | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC (208 V 3ph AC with Derating to 9 kW) | 
| Frequency | 45-66 Hz | 
| Power factor | >0.99 | 
| Leakage current | < 5mA | 
| Overvoltage category | 2 | 
| Pollution degree | 2 | 
| DC-Output static | |
| Load regulation CV | ≤0.05% FS (0 - 100% load, constant input voltage and constant temperature) | 
| Line regulation CV | ≤0.01% FS (208 V - 480 V AC +10% input voltage, constant load and constant temperature) | 
| Stability CV | ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature) | 
| Temperature coefficient CV | ≤30ppm/°C (Following 30 minutes warm up) | 
| Compensation (Remote Sense) | ≤5% UNominal | 
| Load regulation CC | ≤0.1% FS (0 - 100% load, constant input voltage and constant temperature) | 
| Line regulation CC | ≤0.01% FS (208 V - 480 V AC +10% input voltage, constant load and constant temperature) | 
| Stability CC | ≤0.02% FS (Over 8hrs interval following 30 minutes warm-up, constant input voltage, load and temperature) | 
| Temperature coefficient CC | ≤50ppm/°C (Following 30 minutes warm up) | 
| Load regulation CP | ≤0.3% FS (0 - 100% load, constant input voltage and constant temperature) | 
| Load regulation CR | ≤0.3% FS + 0.1% FS current (0 - 100% load, constant input voltage and constant temperature) | 
| Protective functions | |
| OVP | Overvoltage protection adjustable, 0 - 110% UNominal | 
| OCP | Overcurrent protection adjustable, 0 - 110% INominal | 
| OPP | Overpower protection adjustable, 0 - 110% PNominal | 
| OT | Overtemperature protection, output shuts down in case of insufficient cooling | 
| DC-Output dynamic | |
| Rise time 10 - 90% CV | ≤20 ms | 
| Fall time 90 - 10% CV | ≤20 ms | 
| Rise time 10 - 90% CC | ≤10 ms | 
| Fall time 90 - 10% CC | ≤10 ms | 
| Display accuracy | |
| Voltage | ≤0.05% FS | 
| Current | ≤0.1% FS | 
| Insulation | |
| AC-Input to DC-Output | 3750 Vrms (1 Minute), creepage >8 mm | 
| AC-Input to case (PE) | 2500 Vrms | 
| DC-Output to case (PE) | Depending on the model, see model table | 
| DC-Output to Interfaces | 1000 V DC (Model up to 360 V output), 1500 V DC (Model from 500 V output) | 
| Interfaces Digital | |
| Built-in, galvanically isolated | USB, Ethernet (100 MBit) for communication 1x USB Host for data acquisition | 
| Optional, galvanically isolated | CAN, CANopen, RS232, ModBus TCP, Profinet, Profibus, EtherCAT, Ethernet | 
| Interfaces Analog | |
| Built-in, galvanically isolated | 15-pole D-Sub | 
| Signal range | 0 - 10 V or 0 - 5 V (switchable) | 
| Inputs | U, I, P, R, remote control on/off, DC output on/off, resistance mode on/off | 
| Outputs | Monitor U and I, alarms, reference voltage, status DC, status CV/CC | 
| Accuracy U / I / P / R | 0 - 10 V ≤0.2%, 0 - 5 V ≤0.4% | 
| Device configuration | |
| Parallel operation | Up to 64 units of any power class in series 10000, with Master-Slave-Bus and Share-Bus | 
| Safety and EMC | |
| Safety | EN 61010-1 IEC 61010-1 UL 61010-1 CSA C22.2 No 61010-1 BS EN 61010-1 | 
| EMC | EN 55011, class B CISPR 11, class B FCC 47 CFR Part 15B, Unintentional Radiator, class B EN 61326-1 include tests according to: - EN 61000-4-2 - EN 61000-4-3 - EN 61000-4-4 - EN 61000-4-5 - EN 61000-4-6 | 
| Safety protection class | 1 | 
| Ingress Protection | IP20 | 
| Environmental conditions | |
| Operating temperature | 0 - 50 °C | 
| Storage temperature | -20 - 70 °C | 
| Humidity | ≤80% RH, non-condensing | 
| Altitude | ≤2000 m (≤6600 ft) | 
| Mechanical construction | |
| Cooling | Forced air flow from front to rear, temperature controlled fans | 
| Dimensions (B x H x T) | 19“ x 3U x 668 mm (Enclosure only, not over all) | 
| Weight | 32.8 kg (72 lb) | 